Basic ozone generator with timer powered by alternating current. It contains a patented, easily removable ozone cartridge with an ozone production of 4,000 mg/h. With the built-in timer, the treatment time can be set for up to three hours.
It can be used to disinfect car interiors, vehicle air conditioning systems, rooms and standard-sized apartments up to 90 m2.
Model: | HE-150R |
Rated voltage range: | AC 220-240V/50-60Hz |
Rated input power: | 65 W |
Rated fuse current: | 1 or 2 A |
Ceramic board (1 pc): | 95x50 mm |
Air passage: | max. 3 m3/min |
Ozone production: | max. 4,0 g/h (4000 mg/h) |
Max. application area: | 90 m2 |
Noise (dB): | 40 dB |
Dimensions: | 160 x 170 x 220 mm |
Weight: | 2,4 kg |
- Place the device horizontally in the highest possible place in the area to be disinfected and connect it to the power supply.
- There must be not be any people, animals or plants inside the room to be treated.
- Close all windows, door etc in the space to be treated.
- In environments such as hotels with individual heating and air conditioning, switch on the internal air circulation or switch off the air conditioning.
- Set the timer on the device to the desired time (see below) and leave the room. After the set time has elapsed, the device switches itself off.
- Allow at least two hours after the cleaning process before using the treatment room again. Or ventilate the room before further use.
Disinfection area [m2] | Recommended working time [min] |
13,5 - 20 | 10 - 30 |
20 - 40 | 30 - 60 |
40 - 72 | 60 - 100 |
72 - 90 | 100 - 120 |